|
|
 |
 |
 |
 |
 |
APPENDIX 5 - AUTHORIZATION ERRORS
The following lists all the possible errors that may occur during the Authorization
process in the Cybertank Authorization Module (CAM).
DUPLICATE LABEL FOUND
This error occurs when the same label has been used twice in the AI. For a complete
discussion of labels, see Part 1, Section 6.4 of this handbook.
FATAL ERROR: MAXIMUM NUMBER OF LABELS EXCEEDED
This error occurs when you exceed the memory allocated for label names. To remedy,
try using fewer labels or shorter label names. For example, instead of using the
label “SHOOTTANK”, try using something like "SHOOT”.
UNKNOWN COMMAND
This error occurs when an unrecognizable command Is included in the AI. This
normally occurs because of a misspelled or missing word.
USER VARIABLES EXCEEDED
This error occurs if you attempt to use more than 32 User Variables. The only
way to correct this error is to cut down on the number of User Variables. For a
complete discussion of User Variables, see Pert 1, Section 6 of this manual.
DOES NOT COMPUTE IN THE LINE
This error occurs when an instruction in the AI is incomplete. For example,
the instruction “SCAN FOR FRIENDLY TANK” is almost a valid instruction, but not
quite since it is not complete.
VALUE USED IS OUT OF RANGE IN FOLLOWING LINE:
This error occurs when a value in an instruction is not within the allowable
range. For example, in the instruction “TURN TANK TO 9”, the 9 is an illegal value
because you can only turn Your tank to values 0-7.
THE LABEL ... WAS NOT FOUND IN THE FOLLOWING LINE:
This error occurs when an instruction attempts to reference a label which does
not exist.
THE FOLLOWING LINE IS AN ILLEGAL LABEL:
When this error occurs, it signifies that a line in the AI. positioned in the
left margin, is not a valid label. This is often caused by incorrect spacing or
indentation.
THE FOLLOWING LABEL IS TOO LONG:
This error occurs when a label of more than 10 characters is encountered. Shorten
the length of the label.
THE FOLLOWING CAPSULE WAS NOT FOUND:
This error occurs when attempting to INCLUDE a Capsule routine and the Capsule
was not found. To remedy this error, simply insert the Disc which contains the Capsule
routine into any access slot.
IF YOU INCLUDE A CAPSULE, THAT CAPSULE CANNOT INCLUDE ANOTHER
This error occurs when you INCLUDE a Capsule routine and that Capsule attempts
to INCLUDE another. To remedy, you must remove all INCLUDE statements from any Capsules
you wish to INCLUDE.
YOUR TANK MUST BE GIVEN INTELLIGENCE BEFORE IT CAN BE AUTHORIZED
This error occurs if your cybertank has no AI.
YOU ARE MISSING ONE OR MORE ITEMS FROM YOUR TANK’S CHASSIS
This error occurs if you have forgotten to install a needed component on your
cybertank. For example, a cybertank cannot be Authorized if it has no scanner system.
To solve, return to the Chassis Design Module (CDM) and obtain all necessary components.
THE COST OF YOUR TANK’S CHASSIS EXCEEDS YOUR AVAILABLE BUDGET
This error occurs when you attempt to Authorize a cybertank designed by someone
with a higher clearance level, and the equipment on their cybertank exceeds the
budget limitations of your clearance level.
|
 |
|
 |
 |
 |
|